Technical Documentation

Technical drawings NS116

Technical drawings provide supporting documentation for Ausgrid's Network Standards.

160354-1   11kV underground to overhead (ug/oh) construction – combined earthing or HV only

162475_1   Standard construction 11kV pole top capacitors construction detail (Sheet 1)

162475_2   Standard construction 11kV pole top capacitors modification to EDO pole construction detail (Sheet 2)

25121-1   Chamber substation earthing typical installation of electrode

151190-1   Type K kiosk Schneider type T3 layout option plan

151572-1   Type L kiosk Schneider type T2 layout option plan

151573-1   Type J kiosk layout option plan

167433-1   Standard Construction Kiosk Substation Combined HV/ LV Typical Earthing Details

167434-1   Standard construction multiple kiosk substation – combined HV/LV typical earthing details

170234-1   Standard construction 11kV Nulec RL Series Pole Mounted Enclosed Switch General Arrangement

173990-1   Standard Construction Single Kiosk Substation Typical Segregated HV / LV  Earthing Details

220041-1   Standard construction 11kV S&C Intellirupter PulseCloser Without bypass ABS General Arrangement

220251-1   Standard construction 11kV S&C Intellirupter PulseCloser With bypass ABS General Arrangement

224227-1   Standard Construction 11kV Pole Mounted Voltage Regulator With Controlling Intellirupter General Arrangement

224228-1   11kV S&C Intellirupter Pulsecloser Controlling Pole Mounted Regulators With Phase To Earth VT Mounted on a Timber Pole General Arrangement

224229-1   3 Unit 11kV Pole Mounted Regulator With Ground Mounted Control Panel - Construction Detail

224401-1   2 Unit 11kV Pole Mounted Regulator With Ground Mounted Control Panel - Construction Detail

224402-1   2 Unit 11kV Pole Mounted Regulator With Pole Mounted Control Panel - Construction Detail

224403-1   Danger Sign Distribution Substation With Segregated Earth

228821-1   Standard Construction 3ph – 11kV Pole mounted Distribution substation 0-400 kVA General Arrangement

228822-1   Three Phase PT combined and segregated earthing

228831-1   Standard Construction 1 Phase 11kV Pole mounted Distribution substation 0 - 63 kVA General Arrangement

228832-1   Single Phase PT combined and segregated earthing

249447-1   Colorbond Fence Isolating Post Detail

252089-1   Ausgrid Boundary Fences Post and Wire Fence & Post and Rail Fence Details

508786-1   Standard Construction Timber Pole Structure Earthing Arrangement Type SE-M5